Eaton FRCdM Series Residual Current Circuit Breaker, 40A, 3-Pole, 300 mA, Type B, 10 kA, 220 V dc 240V ac

Subtotaal (1 eenheid)*

€ 829,55

(excl. BTW)

€ 1.003,76

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks
Per stuk
1 +€ 829,55

*prijsindicatie

RS-stocknr.:
183-3554
Artikelnummer Distrelec:
304-21-860
Fabrikantnummer:
167905 FRCDM-40/4/03-G/BFQ
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Residual Current Circuit Breaker

Current Rating

40A

Number of Poles

3

Range

FRCdM

Series

FRCdM

Trip Sensitivity

300mA

Tripping Characteristics

Type B

Mount Type

DIN Rail

Terminal Type

Screw

Standards/Approvals

EN 45545-2, IEC 61373, IEC/EN 61008

Depth

70.5mm

Height

80mm

Width

70mm

Breaking Capacity

10kA

Rated DC Voltage

220V dc

Rated AC Voltage

240V ac

Tripping Mechanism

Electromagnetic

Earth Leakage Protection Type

Type B

Application

Industrial

Land van herkomst:
CZ

Eaton RCD Switch, 500A Current Rating, 300mA Trip Sensitivity - FRCDM Series - 167905 FRCDM-40/4/03-G/BFQ


This Eaton residual current device (RCD) switch is an essential safety component in any electrical system. It provides protection against electrocution and also helps to safeguard equipment from electrical fires. The unit automatically detects when there's a difference in the current values of live and neutral wires to prevent an earth leak from causing a critical safety hazard. You can clearly mark this device for quick identification in a control cabinet thanks to its transparent designation plate. It's suited for use in commercial and industrial settings as it's able to withstand high current surges of up to 3kA.

Features & Benefits


• Works digitally without needing manual intervention, for convenience and less risk of human error

• Enhanced current sensitivity, so it can be used with variable frequency drives

• Extended electrical lifespan of up to 4,000 operations for a consistently reliable and long service life

Where are the wiring terminals on this RCB?


This RCB has twin-purpose wiring terminals, which means you can conveniently wire it from either the top or bottom of the unit.

Is this RCD affected by UV light?


As this RCD is protected against UV radiation, it can stand up to the effects of sunlight.

Note

Eaton formerly known as Moeller

Gerelateerde Links