Timeguard 30 A, Active 1 RCD Socket, Plastic, Surface Switched, BS7288 & BS1363-2, 230 V, White, Metallic

Subtotaal (1 eenheid)*

€ 72,58

(excl. BTW)

€ 87,82

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 14 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 18 stuk(s) vanaf 29 januari 2026
  • Plus verzending 30 stuk(s) vanaf 12 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 72,58

*prijsindicatie

RS-stocknr.:
185-3196
Fabrikantnummer:
RCD07MAVN
Fabrikant:
Timeguard
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Timeguard

Product Type

RCD Socket

Material

Plastic

Socket Type

Type G - British

Number of Gangs

1

Pole Configuration

2

RCD Type

Active

Mount Type

Surface

Colour

White, Metallic

Terminal Type

Screw

Outdoor Use

No

Switched

Yes

Screwed/Screwless

Screwed

Switch Type

On-Off Switch

Trip Speed

40ms

Height

87mm

Width

148 mm

Depth

60mm

Range

Timeguard

Standards/Approvals

BS7288 & BS1363-2

Current Rating

30 A

Voltage

230 V

Trip Current

30mA

Minimum Box Depth

25mm

Special Features

Provides Two Protected Switched Socket Outlets for Convenience and Extra Safety

Land van herkomst:
CN

Stay Safe with Valiance+. Dual Flag Technology provides extra protection against the risks of electrocution.


Timeguard's new ’Dual Flag RCD Technology’ is a brand new safety feature stipulated in the latest BS7288:2016 standard. It provides additional safety to both the installer and end user by showing clear visual indication as to the status of the RCD. A RED flag shows the device is ON with a live supply to the appliance. A GREEN flag shows the device is safe with the supply to the appliance switched OFF. For added safety and reliability, Timeguard have used an innovative mechanical flag system due to LED indication systems being less reliable and having a limited life.

Timeguard's new range of Valiance Plus RCDs are fully approved and certified to the new BS7288:2016 standard which now demands a higher resilience to RF devices (EG: mobile phones, walkie-talkies, electronic equipment, etc.), resulting in lower nuisance tripping compared to RCDs built to the old BS standard.

New Dual Flag Technology provides added protection against the risks of electrocution

High EMC Immunity dramatically reduces nuisance tripping

Conforms to BS7288:2016 BS1363-2, and meets latest IET Wiring Regulations

Continues to protect with Lost Neutral /pulsating DC earth fault

Designed, Tested and Certified in the UK

Fits Standard Depth Wall Box

Type A RCDs

Gerelateerde Links