Schmersal AZ16 Safety Switch, Actuator Actuator Included, Fibreglass Reinforced Thermoplastic

Subtotaal (1 eenheid)*

€ 169,42

(excl. BTW)

€ 205,00

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 4 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 169,42

*prijsindicatie

RS-stocknr.:
335-622
Fabrikantnummer:
AZ 16-12ZI-B6L-M16
Fabrikant:
Schmersal
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schmersal

Lock Style

Actuator

Product Type

Safety Switch

Actuator Included

Yes

Safety Contacts

2 NC, NO

Housing Material

Fibreglass Reinforced Thermoplastic

Series

AZ16

Contact AC Voltage

230V ac

IP Rating

IP67

Contact DC Voltage

24V dc

Minimum Operating Temperature

-30°C

Number of Auxiliary Contacts

1

Maximum Operating Temperature

80°C

Hazardous Area Certification

No

Width

52mm

Standards/Approvals

EN IEC 60947-5-1, CCC, EN ISO 14119, EN ISO 13849-1, cULus

Length

30mm

Depth

90mm

Conduit Entry

3 x (M16 x 1.5)

Vrijgesteld

Land van herkomst:
DE

Schmersal AZ16 Series Safety Switch, IP67, Fibreglass Reinforced Thermoplastic Housing - AZ 16-12ZI-B6L-M16


This safety switch provides a compact, rugged interlock designed to control access to hazardous machinery and processes. It operates as an actuator-style safety interlock with integrated safety contacts and an auxiliary contact, suitable for industrial environments where ingress protection and temperature range are important.

Features and Benefits:


• IP67 ingress protection enables use in wet or dusty environments
• Two normally-closed and one auxiliary contact allow safe circuit monitoring
• Accepts 230V AC and 24V DC control voltages for flexible installation
• Fibreglass-reinforced thermoplastic housing offers impact resistance
• Actuator lock-style design supports secure actuation under load

Applications


• Suitable for machine-guard door monitoring in production lines
• Used for conveyor access control in washdown areas
• Ideal for safety circuits requiring mixed AC and DC signals
• Can be used for guarding on robotic cells with temperature variation
• Used with control panels requiring multiple conduit entries

What conduit options are provided for wiring?


It includes three entries sized M16x1.5 to accommodate standard conduit glands.

What temperature limits should be observed during operation?


The unit is rated for continuous use between -30°C and 80°C.

What mechanical form do the safety contacts take?


The device provides two safety contacts in a normally-closed configuration Plus one auxiliary contact.

Is this switch certified for hazardous-area installations?


It is not certified for hazardous-area use and should not be installed where hazardous-area certification is required.

Which standards govern its safety-related performance?


It complies with EN IEC 60947-5-1, EN ISO 14119, EN ISO 13849-1, CCC and cULus approvals.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres