SICK TR4 Safety Switch, RFID Actuator Included, Valox

Subtotaal (1 eenheid)*

€ 192,91

(excl. BTW)

€ 233,42

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 31 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 192,91

*prijsindicatie

RS-stocknr.:
285-4386
Fabrikantnummer:
TR4-SBM10PB
Fabrikant:
SICK
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

SICK

Lock Style

RFID

Product Type

Safety Switch

Actuator Included

Yes

Housing Material

Valox

Series

TR4

Switch Contact Current

200mA

IP Rating

IP69K, IP67

Minimum Operating Temperature

-25°C

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

IEC 60529

Length

67.1mm

Width

30.4mm

Number of Head Directions

5

Land van herkomst:
DO

SICK TR4 Series Safety Switch, IP69K/IP67, 24V DC Supply Voltage - TR4-SBM10PB


This safety switch is a non-contact RFID interlock designed for industrial machine safeguarding. It detects actuator presence via RFID sensing and provides two safe semiconductor outputs for integration into safety circuits. The unit operates from 24V DC and is intended for environments requiring high ingress protection and temperature tolerance. LEDs provide status indication and the device supports diagnostic-capable series connection in a control cabinet.

Features and Benefits:


• SIL3 safety integrity for high-risk functional safety
• Category 4 PL e offering highest performance level
• Dual self-monitoring OSSD outputs for fault-tolerant switching
• IP69K IP67 protection for washdown and high-pressure cleaning
• 10m cable with up to 200m long-connection capability for remote mounting

Applications


• Suitable for safeguarding production machinery with interlocks
• Used for safety gate monitoring in wet environments
• Ideal for series-connected safety architectures with diagnostics
• Can be used for access control on automated lines
• Suitable for facilities requiring temperature resilience from -25°C to 70°C

What signalling outputs are provided for safety integration?


Two self-monitoring semiconductor outputs (OSSDs) supply safe switching with protected output current up to 200mA.

How does the device cope with external electrical faults?


Detection time for external faults such as short-circuits or cross-circuits is specified as up to 100 MS with safe-state behaviour of at least one OSSD switching off.

What mechanical and environmental resistances does it have?


The housing is moulded from Valox and the unit withstands vibration at 10Hz to 55Hz with 3.5mm amplitude and shock of 30g for 11 ms.

What indicators and connections assist installation and commissioning?


Front LEDs provide status display and a 10m PVC-sheathed cable with seven conductors simplifies wiring to control systems.

Are actuators included and how is coding handled?


An actuator is supplied and the pair uses universal RFID coding with a low coding level as defined by standards.

Gerelateerde Links