SICK TR4 Safety Switch, RFID Actuator Included, Valox

Subtotaal (1 eenheid)*

€ 243,41

(excl. BTW)

€ 294,53

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 25 januari 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 243,41

*prijsindicatie

RS-stocknr.:
285-4393
Fabrikantnummer:
TR4-SDU03PB
Fabrikant:
SICK
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

SICK

Lock Style

RFID

Product Type

Safety Switch

Actuator Included

Yes

Housing Material

Valox

Series

TR4

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Switch Contact Current

200mA

IP Rating

IP67, IP69K

Contact AC Voltage

230V ac

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Length

88mm

Number of Head Directions

5

Width

25mm

Standards/Approvals

IEC 60529

Depth

20mm

Land van herkomst:
DO

SICK TR4 Series Safety Switch, IP67, Valox Housing - TR4-SDU03PB


This safety switch is a non-contact RFID interlock designed for safeguarding access points in industrial automation. It provides two monitored semiconductor safety outputs suitable for series connection within a control cabinet and operates from a 24V DC supply. The device is built for continuous industrial use with LED status indication and a 3M PVC cable for straightforward wiring.

Features and Benefits:


• SIL3 safety integrity enabling high-risk application use
• PL e category 4 delivering Advanced fault tolerance
• 200mA output current supporting low-power safety devices
• IP69K protection allowing high-pressure washdown capability
• -25 to 70°C rating preserving operation across temperature ranges

Applications


• Suitable for food-processing machinery with washdown regimes
• Ideal for automated assembly line guard monitoring
• Used for safety fencing where Compact interlocks are required
• Can be used for robotics cell door monitoring with diagnostics
• Suitable for control-cabinet series connection with diagnostics

What type of outputs does it provide?


It provides two self-monitoring semiconductor outputs (OSSDs) with automatic fault detection.

How does the actuator Interface with the sensor?


The system uses an included RFID actuator that pairs to the uniquely coded sensor surfaces for non-contact switching.

What cable details are relevant for installation?


The device has a 3M PVC-sheathed cable, 6.5mm diameter, 0.25mm² conductors and supports extension up to 200m.

How does it behave when a fault is detected?


Upon a fault at least one safety-related semiconductor output switches to the OFF state to maintain a safe condition.

How long is the expected mission time for safety calculations?


The device uses a TM of 20 years for performance assessments in accordance with applicable standards.