Eaton 355A Tag Fuse 76 x 442 mm 7.2kV

Subtotaal (1 eenheid)*

€ 1.621,05

(excl. BTW)

€ 1.961,47

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 31 mei 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 1.621,05

*prijsindicatie

RS-stocknr.:
229-161
Fabrikantnummer:
7.2WKMSJ355 7.2KV 355A 3" MOTORSTART FUSE
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Tag Fuse

Current Rating

355A

Fuse Size

76 x 442 mm

Voltage

7.2kV

Standards/Approvals

DIN 43625, IEC60282-1, VDE 0670-4

Application Category

Motor Protection

Fuse Speed

Back-up

Overall Length

442mm

Length

442mm

Width

76mm

Height

76mm

Series

Bussmann

Vrijgesteld

Land van herkomst:
HU

Eaton Tag Fuse, 355A Current Rating, 7200V Voltage - 7.2WKMSJ355 7.2KV 355A 3 MOTORSTART FUSE


This tag fuse is a high-voltage protective device designed to interrupt fault currents in motor-starter circuits and provide back-up protection in industrial electrical systems. It operates at distribution voltages and is intended for use where motor protection and coordinated isolation are required, delivering dependable interruption for high-energy faults while remaining suitable for installation in standard fuse holders.

Features and Benefits:


• 355A rating enables robust motor-starter protection
• 7200V voltage capacity for high-voltage applications
• Back-up fuse speed offers selective fault-clearing
• Conforms to DIN43625 and IEC60282-1 standards
• VDE0670-4 certification supports regulatory acceptance
• Tag form factor simplifies identification and replacement

Applications


• Suitable for protecting 7.2kV motor starters in industrial plants
• Ideal for use in high-voltage distribution panels
• Used with switchgear requiring back-up overcurrent protection
• Can be used for motor protection in automation systems

What does the fuse’s back-up speed imply for coordination?


Back-up speed means the element is designed to operate for high-energy faults, allowing downstream protective devices to clear smaller faults first while the fuse interrupts larger fault currents when necessary.

How does the tag format assist maintenance teams?


The tag-style construction provides a readily visible identification surface, facilitating quicker replacement and inventory management during routine servicing.

What physical form factors are relevant to mounting?


The product presents a rectangular profile with a narrow cross-section suitable for three-inch holder arrangements and typical high-voltage fuse clips.

Which safety approvals indicate suitability for industrial installations?


Certification to DIN43625, IEC60282-1 and VDE0670-4 demonstrates compliance with recognised standards for high-voltage fuse performance and construction.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.