Eaton 400A Tag Fuse 54 x 150 mm 500V

Subtotaal (1 verpakking van 3 eenheden)*

€ 47,23

(excl. BTW)

€ 57,15

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 06 januari 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Verpakking(en)
Per verpakking
Per stuk*
1 +€ 47,23€ 15,743

*prijsindicatie

RS-stocknr.:
261-576
Fabrikantnummer:
400NHG03BI NH FUSE 400A 500V GL/GG SIZE 03
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Tag Fuse

Current Rating

400A

Fuse Size

54 x 150 mm

Voltage

500V

Standards/Approvals

IEC 60269-1 IEC 60269-2 DIN 43620

Application Category

Wind, Industrial, Utilities, Solar Applications

Fuse Speed

GG

High Rupture Capacity

Yes

Overall Length

150mm

Length

150mm

Height

75mm

Width

53mm

Series

Bussmann

Vrijgesteld

Land van herkomst:
IN

Eaton Tag Fuse, 400A Current Rating, 500V Voltage - 400NHG03BI NH FUSE 400A 500V GL/GG SIZE 03


This tag fuse is a high-capacity protective device designed for industrial power distribution and renewable-energy systems. It provides overcurrent protection within medium-voltage circuits and is intended for use in environments where robust interruption capability and standardised NH sizing are required. The product suits installations demanding a balance between current handling and system protection.

Features and Benefits:


• 400A rating delivers secure circuit protection for heavy loads
• GG time-delay characteristic permits short-duration inrush currents
• 500V voltage capability supports medium-voltage distribution systems
• High rupture capacity enables safe fault interruption without damage
• NH03 form factor ensures compatibility with standard NH holders
• Conforms to IEC and DIN standards for interchangeable use

Applications


• Suitable for wind-turbine electrical protection and monitoring systems
• Ideal for industrial motor feeders and control panels
• Used for solar-array combiner and inverter protection
• Can be used for utility distribution and switchgear circuits
• Used with protection units requiring NH size 03 fuses

What kind of fault currents can it interrupt?


It is manufactured with high rupture capability to clear high fault currents typical in utility and industrial networks, preventing sustained arcing on interruption.

How does the GG characteristic affect protection of motors?


The GG time-delay behaviour allows transient motor start currents to pass without nuisance operation while still clearing sustained overloads.

Which standards ensure compatibility with existing NH fusegear?


It is designed to meet recognised IEC and DIN specifications for NH fuses, enabling interchangeability with compliant fuse holders.

What form factor does it use for panel mounting?


The fuse follows NH size 03 dimensional conventions for insertion into standard NH03 fuse bases.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.