Eaton 450A Tag Fuse 3L 1500V, 205 mm

Subtotaal (1 eenheid)*

€ 470,80

(excl. BTW)

€ 569,67

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 31 maart 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 470,80

*prijsindicatie

RS-stocknr.:
282-6484
Fabrikantnummer:
BSF-450G-3XL15
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Tag Fuse

Current Rating

450A

Fuse Size

3L

Voltage

1500V

Standards/Approvals

RoHS, CE, IEC 60269-7

Fixing Centres

205 mm

Application Category

Battery Storage

Fuse Speed

High

High Rupture Capacity

100 kAIC

Length

205mm

Overall Length

205mm

Height

85mm

Width

75mm

Series

Bussmann

Land van herkomst:
HU

Eaton Tag Fuse, 450A Current Rating, 1500V Voltage - BSF-450G-3XL15


This tag fuse is designed for DC battery installations in renewable energy systems, providing Rapid disconnection to protect circuits within high-voltage battery arrays. It is intended for use where fast interruption of fault currents is required in photovoltaic and storage applications, compliant with relevant international standards for low-voltage battery protection.

Features & Benefits


• 450A continuous rating delivers high-current protection and capacity
• 1500V voltage capability enables use in high-voltage DC strings
• High-speed operation limits energy let-through during faults
• 100kAIC interrupting capacity withstands severe short-circuit currents
• 205mm fixing centres simplify mounting into existing fuse bases

**Applications**


• Suitable for battery storage arrays in commercial installations
• Ideal for DC protection in photovoltaic field strings
• Used with battery management systems in energy storage projects
• Can be used for array isolation in off-grid and hybrid systems

What physical form factor should installers expect for panel planning?


The unit has an overall length of 205mm and a width of 75mm to assist panel layout and clearances.

How does the fuse speed affect system protection?


Rapid clearing characteristics reduce the duration of fault currents, limiting thermal and mechanical stress on connected equipment.

What mounting spacing is required for integrating into fuse holders?


Mounting should accommodate a 205mm centre-to-centre fixing arrangement for secure attachment.

What form factor classification describes its size?


It is supplied in a 3L fuse size suitable for specified holder types.