Endress+Hauser TMT72 Temperature Transmitter Thermocouple, RTD Input 42V, 85 °C, -40 °C
- RS-stocknr.:
- 287-1872
- Fabrikantnummer:
- TMT72-AAA1AAAA1
- Fabrikant:
- Endress+Hauser
Subtotaal (1 eenheid)*
€ 299,55
(excl. BTW)
€ 362,46
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 03 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 299,55 |
*prijsindicatie
- RS-stocknr.:
- 287-1872
- Fabrikantnummer:
- TMT72-AAA1AAAA1
- Fabrikant:
- Endress+Hauser
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Endress+Hauser | |
| Input Type | Thermocouple, RTD | |
| Product Type | Temperature Transmitter | |
| Output Type | Analogue Output | |
| Minimum Temperature Input | -50°C | |
| Maximum Temperature Input | 200°C | |
| Series | TMT72 | |
| Maximum Supply Voltage | 42V | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Hazardous Area Certification | No | |
| Standards/Approvals | CE mark | |
| Alles selecteren | ||
|---|---|---|
Merk Endress+Hauser | ||
Input Type Thermocouple, RTD | ||
Product Type Temperature Transmitter | ||
Output Type Analogue Output | ||
Minimum Temperature Input -50°C | ||
Maximum Temperature Input 200°C | ||
Series TMT72 | ||
Maximum Supply Voltage 42V | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Hazardous Area Certification No | ||
Standards/Approvals CE mark | ||
- Land van herkomst:
- DE
Endress+Hauser TMT72 Series Temperature Transmitter, 200°C Maximum Temperature Input, 42V Maximum Supply Voltage - TMT72-AAA1AAAA1
This temperature transmitter converts sensor inputs into a proportional analogue signal for process monitoring and control. It accepts both thermocouples and resistance temperature detectors and is intended for industrial installations where compact sensing electronics interface with control systems. The unit is CE‑marked and designed to operate across typical ambient conditions encountered in plant environments.
Features and Benefits:
• Accepts thermocouple and RTD inputs, enabling flexible sensor selection
• Outputs analogue signal suitable for 4-20 mA integration with control loops
• Operates from supply voltages up to 42 V, supporting varied power sources
• Measures process temperatures from -50 to 200 °C, covering wide process ranges
• Withstands ambient temperatures from -40 °C to 85 °C for harsh environments
• Compact DIN 44 mm housing for straightforward panel or head mounting
• Outputs analogue signal suitable for 4-20 mA integration with control loops
• Operates from supply voltages up to 42 V, supporting varied power sources
• Measures process temperatures from -50 to 200 °C, covering wide process ranges
• Withstands ambient temperatures from -40 °C to 85 °C for harsh environments
• Compact DIN 44 mm housing for straightforward panel or head mounting
Applications
• Suitable for chemical reactor temperature feedback to PLCs
• Ideal for heat-exchanger outlet temperature monitoring in plant
• Used with thermocouples for high-temperature kiln measurement up to 200 °C
• Can be used for cold-room or freezer-line sensing down to -50 °C
• Used for retrofit into existing head-mounted instrumentation in control cabinets
• Ideal for heat-exchanger outlet temperature monitoring in plant
• Used with thermocouples for high-temperature kiln measurement up to 200 °C
• Can be used for cold-room or freezer-line sensing down to -50 °C
• Used for retrofit into existing head-mounted instrumentation in control cabinets
What input sensor types can it interpret?
It accepts both thermocouple probes and RTD elements, allowing connection to common industrial temperature sensors.
How does the device interface with control systems?
It provides an analogue output compatible with standard 4-20 mA loops for direct connection to PLCs, DCS or chart recorders.
What are the expected environmental operating limits for installation?
The transmitter is specified for ambient operation between -40 °C and 85 °C, enabling use in both low-temperature and elevated ambient locations.
Are there restrictions on maximum measurable process temperature?
The maximum temperature input for the sensing element is 200 °C, with a minimum measurable process temperature of -50 °C.
What certification covers conformity for use in EU markets?
The unit bears the CE mark, indicating conformity with applicable EU directives.
Gerelateerde Links
- Endress+Hauser TMT72 Temperature Transmitter RTD 85 °C, -40 °C
- Endress+Hauser iTEMP TMT72 Temperature Transmitter RTD 85 °C, -40 °C
- Endress+Hauser iTEMP TMT72 Temperature Transmitter Thermocouple 85 °C, -40 °C
- Endress+Hauser iTEMP TMT71 Temperature Transmitter Thermocouple 85 °C, -40 °C
- Endress+Hauser iTEMP TMT162 Temperature Transmitter Thermocouple 85 °C, -40 °C
- Endress+Hauser iTEMP TMT82 Temperature Transmitter Thermocouple 85 °C, -40 °C
- Endress+Hauser iTEMP TMT82 Temperature Transmitter RTD 85 °C, -40 °C
- Endress+Hauser TMT72 Temperature Transmitter PT100 to PT1000 Input 36V -40 °C