Electrotherm Digital Transducer 35V, 85 °C, -40 °C
- RS-stocknr.:
- 913-0866
- Fabrikantnummer:
- LKM 282
- Fabrikant:
- Electrotherm
Bulkkorting beschikbaar
Subtotaal (1 eenheid)*
€ 209,67
(excl. BTW)
€ 253,70
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Voorradig bij de fabrikant
- Klaar voor verzending vanaf 13 juli 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 - 4 | € 209,67 |
| 5 - 9 | € 203,38 |
| 10 + | € 194,99 |
*prijsindicatie
- RS-stocknr.:
- 913-0866
- Fabrikantnummer:
- LKM 282
- Fabrikant:
- Electrotherm
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Electrotherm | |
| Product Type | Digital Transducer | |
| Output Type | 0 to 10 V | |
| Depth | 93mm | |
| Maximum Supply Voltage | 35V | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | EN 61326-1:2006EN 61326-2-3:2006 | |
| Hazardous Area Certification | NO | |
| Alles selecteren | ||
|---|---|---|
Merk Electrotherm | ||
Product Type Digital Transducer | ||
Output Type 0 to 10 V | ||
Depth 93mm | ||
Maximum Supply Voltage 35V | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals EN 61326-1:2006EN 61326-2-3:2006 | ||
Hazardous Area Certification NO | ||
- Land van herkomst:
- DE
LKM 282 Digital Programmable Measuring Transducer
The LKM 282 series is a digital programmable galvanically isolated measuring transducer for thermocouples. The transducer is mounted on standard rails. The LKM 282 transducer was designed to be used in cars. The transducer has a high interference immunity plus a wide range of voltages even a supply voltage of 8V you can obtain a liner output signal of 10V. A slim 6mm design means this transducer takes little space on a standard rail and has optimum shock resistance.
An added benefit to all users is that this measuring transducer can be programmed for a variety of thermocouples all to DIN EN 60584-3.The sensors thermoelectric emfs are converted temperature linearly into the output signal which ranges from 0 to 10V. This is where temperature compensation takes place within the measuring transducer which is configured via a micro USB port.
Input Thermocouples - K, J, L, T, U, E, N, S, B, R, C
Span: 50K
Linearity error: 0.3K
Measurement error: 0.2%
Error of reference junction: +/- 0.5°C
Supply voltage: 8 to 35 VDC, 8 to26 VAC polarity-safe
Max. current consumption: 15mA at 24VDC
Galvanic isolation: 2.5kV
Output: 0 to10V / 10 to 0V current-limited (1mA)
Sensor break: 10V typically 11V
Short circuit: voltage value for room temperature
Response time: 0.5s
TC: 100ppm/K
Humidity: 95%
Mounting: 35mm DIN-rail
Material: polyester
Dimensions: 100x6x93mm (HxWxD)
Type of terminals: screw terminals spring-cage terminals are possible
Clamping range: 0.2 to 2.5mm²
Weight: approx.54g
Vibration: 147 to 500Hz / 300 m/s² 500Hz to 2K / 200 m/s²
Galvanically Isolated Digital Programmable Measuring Transducer
Approvals
EN61326-1:2006
EN61326-2-3:2006
EN61326-2-3:2006
Gerelateerde Links
- Electrotherm Digital Transducer 35V -40 °C
- Electrotherm 261 Digital Transducer 35V -40 °C
- Electrotherm LKM 273 Digital Transducer 35V -25 °C
- Electrotherm 264 Digital Transducer PT100 to PT1000 Input 35V -25 °C
- Electrotherm LKM 145 Temperature Transmitter 35V dc -40 °C
- LKMelectronic LKM 224 Temperature Transmitter 35V -40 °C
- LKMelectronic LKM 211 Temperature Transmitter 35V -40 °C
- LKMelectronic LKM 211 Temperature Transmitter Thermocouple Input 35V -40 °C