Lapp UNITRONIC BUS Series Bus Cable, 3 Pairs, 0.22 mm², Violet Sheath Polyvinyl Chloride
- RS-stocknr.:
- 433-361
- Fabrikantnummer:
- 2170205
- Fabrikant:
- Lapp
Subtotaal (1 rol van 100 meter)*
€ 131,96
(excl. BTW)
€ 159,67
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 131,96 | € 1,32 |
*prijsindicatie
- RS-stocknr.:
- 433-361
- Fabrikantnummer:
- 2170205
- Fabrikant:
- Lapp
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lapp | |
| Number of Pairs | 3 | |
| Product Type | Bus Cable | |
| Cross Sectional Area | 0.22 mm² | |
| Jacket Colour | Violet | |
| Outside Diameter | 7.2mm | |
| Conductor Type | Stranded | |
| Jacket Material | Polyvinyl Chloride | |
| Minimum Operating Temperature | 30°C | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | EN 60332 1 2, IEC 60332 1 2, EU 2014/35/EU, EU 2011/65/EU | |
| Voltage | 25V | |
| Series | UNITRONIC BUS | |
| Conductor Material | Bare Copper | |
| Fire Behaviour | Flame Retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 | |
| Alles selecteren | ||
|---|---|---|
Merk Lapp | ||
Number of Pairs 3 | ||
Product Type Bus Cable | ||
Cross Sectional Area 0.22 mm² | ||
Jacket Colour Violet | ||
Outside Diameter 7.2mm | ||
Conductor Type Stranded | ||
Jacket Material Polyvinyl Chloride | ||
Minimum Operating Temperature 30°C | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals EN 60332 1 2, IEC 60332 1 2, EU 2014/35/EU, EU 2011/65/EU | ||
Voltage 25V | ||
Series UNITRONIC BUS | ||
Conductor Material Bare Copper | ||
Fire Behaviour Flame Retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 | ||
- Land van herkomst:
- IT
The Lapp Cable is designed for bus systems with a data transmission rate of up to 10 MBit/s. The conductors are twisted into pairs to ensure maximum interference suppression of individual signals. Copper screening provides protection against external electromagnetic influences. This cable is intended for limited flexible use and permanent installation in dry and damp indoor environments.
Screened
Stranded bare copper conductor
Polyolefin insulation
Gerelateerde Links
- Lapp UNITRONIC BUS Series Bus Cable Violet Sheath Polyurethane
- Lapp UNITRONIC BUS Series Bus Cable 0.5 mm², Violet Sheath Polyurethane
- Lapp UNITRONIC BUS Series Bus Cable 0.25 mm², Violet Sheath Polyurethane
- Lapp UNITRONIC BUS Series Bus Cable 0.25 mm², Violet Sheath Polyurethane
- Lapp UNITRONIC BUS Series Bus Cable 0.64 mm², Violet Sheath Thermoplastic Elastomer
- Lapp UNITRONIC BUS Series Bus Cable 0.75 mm², Violet Sheath Polyvinyl Chloride
- Lapp UNITRONIC BUS Series Bus Cable Black Sheath Polyvinyl Chloride
- Lapp UNITRONIC BUS Series Bus Cable 2.5 mm², Black Sheath Rubber