Lapp UNITRONIC LiYCY Series Data Cable, 12 Cores, 0.5 mm², Screened, 20 AWG, 100m, Screened Shield, LiYCY Cable

Subtotaal (1 rol van 100 meter)*

€ 536,75

(excl. BTW)

€ 649,47

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 5 stuk(s) klaar voor verzending vanaf een andere locatie
  • Plus verzending 6 stuk(s) vanaf 27 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 536,75€ 5,368

*prijsindicatie

RS-stocknr.:
491-8523
Artikelnummer Distrelec:
304-33-423
Fabrikantnummer:
0034612
Fabrikant:
Lapp
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Lapp

Cross Sectional Area

0.5 mm²

Number of Cores

12

American Wire Gauge

20 AWG

Screened/Unscreened

Screened

Length

100m

Shield Type

Tinned Copper Braid

Sheath Colour

Grey

CPR Certification

Eca

Cable Type

LiYCY

Outer Diameter

9.6mm

Outer Sheath Material

PVC

Cable Shape

Multicore

Standards Met

CE

Fire Behaviour

Flame Retardant

Core Strands

16/0.20 mm

Minimum Operating Temperature

-40°C

Series

UNITRONIC LiYCY

Voltage Rating

500 V

Maximum Operating Temperature

+80°C

Shielded/Unshielded

Shielded

Land van herkomst:
DE

Lapp UNITRONIC LiYCY Series Data Cable, 12 Cores, Grey Sheath - 0034612


This Lapp multicore cable is a shielded data cable. With technical specifications including a 20 AWG cable, tinned copper braid, and a flame retardant PVC outer sheath, this cable is designed for low frequency applications in various industries.

Features & Benefits


• Multicore cable design with 16/0.20 mm core strands for flexibility and durability
• Shielded with tinned copper braid for protection against electromagnetic interference
• Flame retardant PVC outer sheath ensures safety in different environments
• CPR Certification Eca for compliance with safety standards

Applications


• Ideal for use in computer systems, instrumentation technology, office equipment, and balances
• Suitable for fixed installations in dry and damp interiors, not recommended for outdoor use

Can it withstand extreme temperatures?


This cable has a minimum operating temperature of -40 °C and a maximum operating temperature of +80 °C.

Is it suitable for outdoor installations?


This shielded data cable is not appropriate for outdoor usage due to its design for dry and damp interiors.

Will it provide protection against electromagnetic interferences?


The tinned copper braid shield in this cable offers protection against electromagnetic interferences.

Gerelateerde Links