Festo Pneumatic 2 Port Actuated Ball Valve - Actuator

Momenteel niet beschikbaar
We weten niet of dit artikel weer voorradig zal zijn, het wordt door de fabrikant stopgezet.
RS-stocknr.:
271-7430
Fabrikantnummer:
VZBC-32-FF-40-22-F0405-V4V4T-PP60-R-90-C
Fabrikant:
Festo
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Festo

Product Type

Actuated Ball Valve

Number of Ports Supported

2

Actuator Type

Pneumatic

Function

Actuator

Standards/Approvals

ISO 8573-1:2010, ATEX

Model Number

1913369

Land van herkomst:
DE

Festo Actuated Ball Valve, Pneumatic Actuator, 2 Ports Supported - VZBC-32-FF-40-22-F0405-V4V4T-PP60-R-90-C, Numeric Part Number:1913369


This actuated ball valve is a pneumatic-driven, two-port valve designed to control fluid flow in automated systems. It combines a semi-rotary drive with in-line installation to provide quarter-turn operation for compressed air, inert gases and NEUTRAL fluids across a broad temperature range and in potentially explosive atmospheres.

Features and Benefits:


• DN32 nominal size delivers high flow capacity of Kv105m³/h
• Operates at 6bar-8.4bar for predictable actuation performance
• Handles media temperatures from -10°C to200°C for process flexibility
• Stainless-steel construction resists high corrosion stress CRC3
• PTFE-reinforced Seals enable compatibility with NEUTRAL fluids
• ATEX zone1/2/21/22 compliance permits use in explosive areas

Applications


• Suitable for automated control of compressed-air systems
• Ideal for pneumatic quarter-turn duties in chemical plants
• Used with inert-gas distribution in hazardous zones
• Can be used for NEUTRAL fluid isolation in process lines
• Appropriate for high-temperature service up to200°C

What type of actuation medium is required?


It requires a pneumatic supply meeting ISO 8573-1:2010 and supports lubricated operation where lubrication is applied.

Which materials contact the process media?


Wetted parts comprise high-alloy stainless steel for the ball and housing and PTFE-reinforced seals.

What ambient conditions does it tolerate for safe operation?


It can be installed where ambient temperature ranges from -10°C to 80°C and within ATEX-designated explosion zones.

How is the valve mounted in a pipeline?


The unit is designed for in-line installation using a ring housing with threaded flange connections.