Recom REM3 DC/DC Converter, 5V dc/ 600 mA, 36V dc Input, 18V Input 3 W, Through Hole, 105 °C Max Temp -40 °C Min Temp,

Bulkkorting beschikbaar
Bekijk bulkkorting

Subtotaal (1 tube van 7 eenheden)*

€ 442,92

(excl. BTW)

€ 535,93

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 03 december 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.

Tube(s)
Per tube
Per stuk*
1 - 4€ 442,92€ 63,274
5 - 9€ 429,62€ 61,374
10 - 24€ 416,34€ 59,477
25 - 49€ 403,05€ 57,579
50 +€ 389,77€ 55,681

*prijsindicatie

RS-stocknr.:
166-6503
Fabrikantnummer:
REM3-2405S/A
Fabrikant:
Recom
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Recom

Output Voltage 1

5V dc

Product Type

DC/DC Converter

Maximum Input Voltage

36V dc

Minimum Input Voltage

18V

Output Current 1

600mA

Mount Type

Through Hole

Input Ratio

2:1

MTBF

6444000h

Number of Outputs

1

Output Voltage Adjustment Range

±10 %

Number of Pins

24

Isolation Voltage

5kV ac

Package Type

DIP-24

Maximum Output Power

3W

Depth

10.4mm

Length

31.8mm

Series

REM3

Standards/Approvals

No

Width

20.3mm

Maximum Operating Temperature

105°C

Efficiency

84.5%

Minimum Operating Temperature

-40°C

Land van herkomst:
TW

Recom 3W DIP Single/Dual Output Regulated Isolated Medical DC-DC Converter - REM3 Series


The Recom REM3 is a series of medical grade, regulated DC/DC converters, featuring reinforced 5kVAC/1 minute isolation, low 2μA leakage and are 60601-1 3rd Ed. certified for 250VAC continuous working. The compact DIP24 package of these DC-DC converters offers tightly regulated single and dual outputs, even under no-load conditions. The outputs of the REM3 Series of converters are short circuit and overload protected. The DC-DC converters are fully certified to CB, IEC/EN and ANSI/AAMI standards and carry the CE and UL marks.

Reinforced Insulation for 250VAC Working Voltage

Clearance and Creepage Distance: 8mm

5kVAC I/P to O/P 2MOPP Isolation

2μA Patient Leakage Current

Industry Standard Pinout

2:1 and 4:1 Wide Input Range

Approvals

CB, IEC/EN, ANSI/AAMI, CE and UL

Standards

UL-60950-1, EN-55011, EN-55022, IEC/EN-60950-1, IEC/EN-60601-1