Fluke 789/771 GEAR Digital Multimeter, 0.4 V Min, 1000 V Max CAT III, CAT IV

Subtotaal (1 eenheid)*

€ 2.366,00

(excl. BTW)

€ 2.862,86

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 4 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 2.366,00

*prijsindicatie

RS-stocknr.:
458-154
Fabrikantnummer:
FLUKE-789/771 GEAR
Fabrikant:
Fluke
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke

Model Number

789/771 GEAR

Product Type

Digital Multimeter

Tester Type

Digital Multimeter

Maximum Test Voltage

1000V

Minimum Test Voltage

0.4V

Display Type

Digital

Test Current

20mA

Battery Life

140h

Power Source

Battery

Battery Type

Four AA alkaline

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

55°C

Safety Category Level

CAT III, CAT IV

Safety Category Voltage

1000V, 600V

Width

100mm

Length

203mm

Height

50mm

Standards/Approvals

CAT IV 600 V/CAT III 1000 V, IEC610101, Pollution Degree 2/IEC610102033

Weight

600g

Land van herkomst:
US

Fluke Digital Multimeter, 1000V Maximum Test Voltage, 20mA Test Current - FLUKE-789/771 GEAR


This digital multimeter combines a safety-rated handheld DMM with mA loop functionality for troubleshooting and calibration in industrial environments. It measures AC/DC volts and current, resistance, frequency and continuity, and can source or simulate 0-20mA loops while operating from battery power. The instrument is suitable for field technicians who need a single portable tool that supports current loop diagnostics and routine electrical measurements.

Features and Benefits:


• 0.05% 20mA sourcing accuracy for precise loop calibration
• 1000V maximum test voltage for high-voltage diagnostics
• CAT IV 600V/CAT III 1000V safety rating for industrial environments
• True-rms measurement to 1000V for accurate AC readings
• Four AA battery operation providing 140 h typical runtime
• Frequency measurement to 20 kHz for signal verification

Applications


• Suitable for commissioning current loop transmitters and sensors
• Ideal for maintenance of industrial control loops and PLCs
• Used for field verification of AC power and signal integrity
• Can be used for on-site resistance and continuity checks
• Used with HART-enabled loops when loop power and resistor required

What loop power capabilities are available when supplying a loop?


One variant provides a minimum 24 V loop supply capable of driving 250 Ω at 20 mA for powering field devices.

How does it behave when sourcing current into higher impedance loops?


In internal battery sourcing mode it supplies up to 24 V compliance and will drive 1,200 Ω at 20 mA.

What environmental range supports field use across seasons?


It operates between -20 °C and 55 °C and can be stored from -40 °C to 60 °C for varied site conditions.

Which measurement modes assist in capturing transient behaviour?


Min/Max/Average/Hold and Relative modes are available to Record and analyse variable signals.

What protection exists for jack-to-earth voltage exposure?


The maximum voltage that may be applied between any jack and earth is 1000 V RMS.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.