Fluke 116 Digital Digital Multimeter True RMS, 600 μA ac, 600 μA dc, 600 V ac, RSCAL Calibrated
- RS-stocknr.:
- 625-0560
- Fabrikantnummer:
- 2583601
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 417,00
(excl. BTW)
€ 504,57
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- Plus verzending 19 stuk(s) vanaf 05 juni 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 417,00 |
*prijsindicatie
- RS-stocknr.:
- 625-0560
- Fabrikantnummer:
- 2583601
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Model Number | 116 | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum Resistance Measurement | 40mΩ | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum AC Current Measurement | 600μA ac | |
| Maximum DC Current Measurement | 600μA dc | |
| True RMS | Yes | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| DC Voltage Accuracy | ±0.5 % rdg + 2 Digits | |
| DC Current Accuracy | ±1 % rdg + 2 Digits | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| DC Current Resolution | 0.1μA dc | |
| DC Voltage Resolution | 0.1 mV dc | |
| AC Current Resolution | 0.1μA ac | |
| AC Voltage Resolution | 0.1mV ac | |
| Maximum Frequency | 1kHz | |
| Minimum Operating Temperature | -10°C | |
| Resistance Measurement Accuracy | ±1.5 % rdg + 2 Digits | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 400h | |
| Height | 167mm | |
| Length | 46mm | |
| Standards/Approvals | No | |
| Width | 84mm | |
| Weight | 550g | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V | |
| Battery Type | Alkaline | |
| Calibrated | RSCAL | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Model Number 116 | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum Resistance Measurement 40mΩ | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum AC Current Measurement 600μA ac | ||
Maximum DC Current Measurement 600μA dc | ||
True RMS Yes | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
DC Voltage Accuracy ±0.5 % rdg + 2 Digits | ||
DC Current Accuracy ±1 % rdg + 2 Digits | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
DC Current Resolution 0.1μA dc | ||
DC Voltage Resolution 0.1 mV dc | ||
AC Current Resolution 0.1μA ac | ||
AC Voltage Resolution 0.1mV ac | ||
Maximum Frequency 1kHz | ||
Minimum Operating Temperature -10°C | ||
Resistance Measurement Accuracy ±1.5 % rdg + 2 Digits | ||
Maximum Operating Temperature 50°C | ||
Battery Life 400h | ||
Height 167mm | ||
Length 46mm | ||
Standards/Approvals No | ||
Width 84mm | ||
Weight 550g | ||
Safety Category Level CAT III | ||
Safety Category Voltage 600V | ||
Battery Type Alkaline | ||
Calibrated RSCAL | ||
Vrijgesteld
- Land van herkomst:
- CN
Fluke Multimeter, 600V Maximum DC Voltage Measurement, True RMS Functionality - FLUKE-116 EUR
Features & Benefits
• 600V and 600A ranges support high-voltage and high-current tasks
• Microamp input checks flame sensors and low-current circuits
• 1kHz frequency range captures up to 50kHz on voltage inputs
• LoZ mode prevents false readings from ghost voltages
• 400h battery life enables extended field operation without frequent replacement
**Applications**
• Ideal for electricians verifying AC and DC supply integrity
• Used for testing flame-sensor circuits and microamp signals
• Can be used with temperature probes for refrigeration maintenance
• Used for capacitance and frequency checks in control panels
What battery type does it use and how long will it operate typically?
How does the instrument perform under poor lighting conditions?
What protection and safety features are incorporated for field use?
Which measurements include capacitance and what ranges are available?
How does the meter capture transient signal behaviour?
Standards
Contents
Gerelateerde Links
- Fluke 116 Digital Digital Multimeter True RMS 600 μA dc UKAS Calibrated
- Fluke 116 Digital Digital Multimeter True RMS 600 μA dc, 600 V ac
- Metrix Handheld Digital Multimeter True RMS, 600 V ac - RSCAL Calibrated
- Metrix Handheld Digital Multimeter True RMS, 600 V ac - UKAS Calibrated
- Fluke 113 Fluke 113 Digital Digital Multimeter True RMS UKAS Calibrated
- Fluke 113 Fluke 113 Digital Digital Multimeter True RMS RSCAL Calibrated
- Fluke 177 Digital Digital Multimeter True RMS, UKAS Calibrated
- Fluke 177 Digital Digital Multimeter True RMS, RSCAL Calibrated