Fluke 6500-2 PAT Testing Kit, Class II, Class I Test Type
- RS-stocknr.:
- 798-4343
- Artikelnummer Distrelec:
- 302-57-561
- Fabrikantnummer:
- 6500-2 DE KIT
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 2.932,00
(excl. BTW)
€ 3.547,72
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending 1 stuk(s) vanaf 08 juni 2026
- Plus verzending 2 stuk(s) vanaf 15 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 2.932,00 |
*prijsindicatie
- RS-stocknr.:
- 798-4343
- Artikelnummer Distrelec:
- 302-57-561
- Fabrikantnummer:
- 6500-2 DE KIT
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | PAT Testing Kit | |
| Tester Type | Appliance Checker | |
| Test Type | Class II, Class I | |
| Testing Method | Manual | |
| Download | Yes | |
| Power Source | Mains | |
| Model Number | 6500-2 | |
| Minimum Supply Voltage | 4V ac | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 40°C | |
| Width | 275mm | |
| Height | 114mm | |
| Weight | 3.13kg | |
| Length | 200mm | |
| Standards/Approvals | BS EN 50678, BS EN 50699 | |
| Maximum Supply Voltage | 240V | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type PAT Testing Kit | ||
Tester Type Appliance Checker | ||
Test Type Class II, Class I | ||
Testing Method Manual | ||
Download Yes | ||
Power Source Mains | ||
Model Number 6500-2 | ||
Minimum Supply Voltage 4V ac | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 40°C | ||
Width 275mm | ||
Height 114mm | ||
Weight 3.13kg | ||
Length 200mm | ||
Standards/Approvals BS EN 50678, BS EN 50699 | ||
Maximum Supply Voltage 240V | ||
Vrijgesteld
- Land van herkomst:
- RO
Fluke PAT Testing Kit, 240V Maximum Supply Voltage, 3.13kg Weight - 6500-2 DE KIT
This PAT testing kit is a mains-powered appliance tester designed for on-site electrical safety assessments. It performs manual testing of Class I and Class II equipment and is intended for professionals in automation, electronics, electrical and mechanical sectors who require portable diagnostic capability within typical indoor environments.
Features & Benefits
• Mains operation up to 240V allows standard site testing
• Minimum test voltage 4V ac enables low-voltage continuity checks
• Supports Class I and Class II testing for varied appliance types
• Conforms to BS EN 50678 and BS EN 50699 for standardised procedures
• Lightweight 3.13 kg construction eases transport between sites
• Operates reliably across 0–40 °C for typical workshop conditions
• Minimum test voltage 4V ac enables low-voltage continuity checks
• Supports Class I and Class II testing for varied appliance types
• Conforms to BS EN 50678 and BS EN 50699 for standardised procedures
• Lightweight 3.13 kg construction eases transport between sites
• Operates reliably across 0–40 °C for typical workshop conditions
**Applications**
• Suitable for routine safety checks in manufacturing facilities
• Ideal for electrical maintenance teams performing asset audits
• Used with portable equipment inventories during site moves
• Can be used for compliance testing in service and repair workshops
• Ideal for electrical maintenance teams performing asset audits
• Used with portable equipment inventories during site moves
• Can be used for compliance testing in service and repair workshops
How is the unit powered during inspections?
It runs from the mains supply and is configured for operation on 240V circuits.
Which classes of appliances can it evaluate?
It performs manual tests on both Class I earthed appliances and Class II double-insulated items.
What environmental conditions are acceptable for use?
The tester is specified to function between 0 °C and 40 °C, covering standard internal and sheltered external locations.
Is the tester suitable for frequent relocation between sites?
At 3.13 kg the instrument is Compact enough for regular transport and on-site portability.
Which regulatory test standards does it follow?
The unit is manufactured to meet the requirements of BS EN 50678 and BS EN 50699 for PAT testing procedures.
Standards
DIN VDE0404-1 and DIN VDE0404-2, IEC/EN 61557, part 1, 2, 4, 6, 10, CAT II, 300 V, pol 2
Supplied with
SPSCAN6000 Barcode Scanner, APP 1000 Barcode Appliance Number Labels, Fail 100s Appliance Fail Labels, Pass 560R Appliance Pass Labels, EXTL 100 Extension Lead Test Adaptor, TruTest Software.
Gerelateerde Links
- Fluke 6500 PAT Testing Kit Class I Test Type
- Fluke PAT Testing Kit Class II Test Type
- Fluke 6500 PAT Tester Class II Test Type
- Martindale HPAT600KIT1-2 PAT Testing Kit Class II Test Type
- Martindale HPAT PAT Testing Kit Class II Test Type
- Fluke 6200 PAT Tester Class II Test Type
- Fluke Adapter PAT Testing Adapter, For Use With 6500 Series
- Seaward PAT Testing Kit UKAS