Fluke 718 -850 mbar to 7 bar Pressure Calibrator, RSCAL
- RS-stocknr.:
- 352-0260
- Fabrikantnummer:
- FLUKE-718 100
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 4.426,00
(excl. BTW)
€ 5.355,46
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 5 stuk(s) vanaf 28 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 4.426,00 |
*prijsindicatie
- RS-stocknr.:
- 352-0260
- Fabrikantnummer:
- FLUKE-718 100
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Battery Type | Alkaline | |
| Product Type | Pressure Calibrator | |
| Maximum Pressure Measurement | 7bar | |
| Accuracy | ±0.015 % | |
| Minimum Pressure Measurement | -850mbar | |
| Resolution | 0.1 mbar | |
| Data Logging | No | |
| Model Number | 718 | |
| Display Type | LCD | |
| Current Loop Measurement | Yes | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Battery Life | 20h | |
| Maximum Operating Temperature | 55°C | |
| Length | 216mm | |
| Width | 94mm | |
| Height | 66mm | |
| Standards/Approvals | No | |
| Hazardous Area Certification | No | |
| Calibrated | RSCAL | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Battery Type Alkaline | ||
Product Type Pressure Calibrator | ||
Maximum Pressure Measurement 7bar | ||
Accuracy ±0.015 % | ||
Minimum Pressure Measurement -850mbar | ||
Resolution 0.1 mbar | ||
Data Logging No | ||
Model Number 718 | ||
Display Type LCD | ||
Current Loop Measurement Yes | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Battery Life 20h | ||
Maximum Operating Temperature 55°C | ||
Length 216mm | ||
Width 94mm | ||
Height 66mm | ||
Standards/Approvals No | ||
Hazardous Area Certification No | ||
Calibrated RSCAL | ||
Vrijgesteld
- Land van herkomst:
- DE
Fluke Pressure Calibrator, 7 Bar Maximum Pressure Measurement, ±0.015 % Accuracy - FLUKE-718 100
This pressure calibrator is a compact, battery-powered handheld instrument designed to generate and measure pneumatic pressure and to verify current loop signals for industrial calibration of transmitters, gauges and switches. It operates in field conditions between -10°C and 55°C and displays simultaneous pressure and current readings on an LCD for straightforward on-site diagnostics.
Features and Benefits:
• ±0.015% mA accuracy delivers precise current measurement
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
Applications
• Suitable for calibrating pressure transmitters and gauges on-site
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
What type of batteries does it use and how are they installed?
It uses alkaline 9 V batteries (ANSI/NEDA 1604A or IEC 6LR61) and requires two cells installed in the battery compartment.
How does the pump handle exposure to process fluids?
The pump includes protective check valves and a serviceable valve assembly that can be cleaned in the field using isopropyl alcohol and Basic tools.
What display information is available simultaneously during calibration?
The LCD shows five‑digit pressure and current readings at the same time for concurrent measurement review.
How does the unit perform switch testing?
A dedicated switch test function captures trip and reset points, aiding Faster and more accurate pressure switch assessments.
What environmental stresses can the instrument withstand during transport?
It tolerates a 1 m drop test and random vibration at 2 g across 5 Hz-500 Hz frequencies.
Supplied with
protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)
Gerelateerde Links
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator, RSCAL
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator, RSCAL
- Fluke 718 -850 mbar to 7 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator, RSCAL
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator, RSCAL
- Fluke 717 -850 mbar to 7 bar Pressure Calibrator, RSCAL