Allen Bradley 1492-RCDA RCD, 63A, 3+N Pole, 300mA, Type A

Subtotaal (1 eenheid)*

€ 417,36

(excl. BTW)

€ 505,01

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 27 april 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 417,36

*prijsindicatie

RS-stocknr.:
136-8597
Fabrikantnummer:
1492-RCDA4C63S
Fabrikant:
Allen Bradley
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Allen Bradley

Circuit Breaker Type

RCD

Current Rating

63A

Number of Poles

3+N

Trip Sensitivity

300mA

Tripping Characteristics

Type A

Series

1492-RCDA

Terminal Contact Type

Screw

Overall Dimensions

70 x 88 x 75mm

Overall Depth

75mm

Overall Width

88mm

Reset Actuator Type

Toggle Switch

Break Time

Time Delay

Rated AC Voltage

230 V, 400V

Overall Length

70mm

Mounting Style

DIN Rail Mount

Breaking Capacity at Maximum Voltage Rating

1 (Residual) kA, 10 (Short-Circuit) kA

Land van herkomst:
IT

1492 Series


Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.

Features & Benefits


2 or 4 pole versions
DIN Rail mount
Screw Terminals

Allen Bradley RCD Switch, 10kA Short Circuit Breaking Capacity, DIN Rail Mount - 1492-RCDA4C63S


When you need to protect your system from electrical faults, try this Allen Bradley RCD switch from Rockwell Automation. It instantly breaks a circuit if there's an earth leakage, so helps to protect people against shocks and reduces the risk of equipment damage. Once the device has tripped a faulty circuit, it's easy for you to manually reset it using the front toggle switch. Compact dimensions of 88 (H) x 70 (W) x 67mm (D) mean you benefit from maximum packing efficiency in your control cabinet.

• Electrical endurance of 10,000 operations for an extended service life
• Fast-clip mounting, so snaps quickly onto a DIN rail
• Wide operating temperature range between -25°C and +55°C for use in demanding settings
• Screw terminals hold wires securely for reduced maintenance

Standards and Certifications


• IEC
• EN

How quickly does this RCD react to an earth leakage?


This is a type-A residual current circuit breaker, which means it has a tripping time of approximately 40ms so reacts almost instantly to an earth leakage.

What's the operational voltage range of this RCD?


This device has an operational voltage range between 230 and 400V AC, so is a versatile choice.


Allen Bradley RCBs

Gerelateerde Links