Eaton 10A Tag Fuse 36 x 257 mm 3.6kV

Subtotaal (1 verpakking van 5 eenheden)*

€ 845,37

(excl. BTW)

€ 1.022,90

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 09 maart 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Verpakking(en)
Per verpakking
Per stuk*
1 +€ 845,37€ 169,074

*prijsindicatie

RS-stocknr.:
228-959
Fabrikantnummer:
3.6WJON610
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Tag Fuse

Current Rating

10A

Fuse Size

36 x 257 mm

Voltage

3.6kV

Standards/Approvals

BS 2692-1

Application Category

Motor Protection

Fuse Speed

Back-up

High Rupture Capacity

50 kAIC

Overall Length

257mm

Length

257mm

Diameter

35mm

Width

36mm

Height

36mm

Series

Bussmann

Vrijgesteld

Land van herkomst:
HU

Eaton Tag Fuse, 10A Current Rating, 3.6kV Voltage - 3.6WJON610


This tag fuse provides overcurrent protection for motors in medium-voltage installations. Designed for use where a back-up protective device is required, it operates at 3.6 kV and is intended to isolate faults while maintaining system integrity in industrial electrical systems.

Features and Benefits:


• 10A rating for controlled tripping of motor circuits
• 50 kAIC high rupture capacity to interrupt large fault currents
• Back-up fuse speed to protect primary protective devices
• Complies with BS 2692-1 for standardised performance
• 36mm diameter for compatibility with tag fuse holders
• 257mm overall length for straightforward fitting in existing panels

Applications


• Suitable for motor protection in automation panels
• Ideal for use in industrial motor control centres
• Used with medium-voltage distribution switchgear
• Can be used for protective coordination in factory installations

What voltage systems can it be used on?


It is specified for 3.6 kV systems and suitable for equipment rated at that voltage.

How does the fuse handle very high fault currents?


Its high rupture capability of 50 kAIC enables safe interruption of substantial short-circuit currents.

What physical form factor should be considered for mounting?


The fuse adopts a cylindrical tag style with an overall length of 257mm to match tag-type holders.

Is this device intended for primary or secondary protection roles?


It functions as a back-up protective element, designed to operate in coordination with primary protective devices.

What current rating is available for coordination studies?


A fixed current rating of 10A should be used when performing protection coordination.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.