Eaton 200A Tag Fuse 46 x 461 mm 3.6kV

Subtotaal (1 verpakking van 3 eenheden)*

€ 2.248,96

(excl. BTW)

€ 2.721,24

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 08 maart 2027
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Verpakking(en)
Per verpakking
Per stuk*
1 +€ 2.248,96€ 749,653

*prijsindicatie

RS-stocknr.:
258-972
Fabrikantnummer:
3.6WFGHD200
Fabrikant:
Eaton
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Eaton

Product Type

Tag Fuse

Current Rating

200A

Fuse Size

46 x 461 mm

Voltage

3.6kV

Standards/Approvals

IEC 60282-1

Application Category

Motor Protection

Fuse Speed

Back-up

Length

359mm

Overall Length

359mm

Width

76mm

Height

76mm

Series

Bussmann

Vrijgesteld

Land van herkomst:
HU

Eaton Tag Fuse, 200A Current, 3.6kV Voltage - 3.6WFGHD200


This tag fuse is designed to protect motor circuits in industrial electrical systems by interrupting fault currents at high voltage levels. It operates as a back-up protective device for motors, providing overcurrent isolation in installations compliant with recognised international fuse standards. The component is intended for use where controlled interruption and motor safeguarding are required.

Features and Benefits:


• 200A rating offers consistent motor overcurrent protection
• 3.6kV voltage capability permits use in high-voltage networks
• Back-up fuse characteristic supports selective coordination
• IEC60282-1 conformity ensures standardised performance testing
• 76mm width facilitates installation in tag fuse holders
• 359mm overall length enables compatibility with long-format fuse assemblies

Applications


• Suitable for motor control centres in manufacturing plants
• Ideal for protection of industrial drive systems and starters
• Used with switchgear in medium-voltage distribution panels
• Can be used for maintenance spares in electrical service fleets

What type of circuit fault does it primarily address?


It is intended to clear sustained overcurrents and provide back-up interruption for motor fault conditions rather than instantaneous short-circuit discrimination.

Which physical attribute affects mounting compatibility?


The fuse’s overall length of 359mm and 76mm width determine fitment in elongated tag fuse holders and associated clips.

How does the device’s voltage rating influence selection?


The 3.6kV rating defines its suitability for medium/high-voltage motor circuits where insulation and switching equipment are specified for that voltage class.

What characteristic should be checked for coordination with upstream protection?


Its back-up speed classification should be compared with upstream protective devices to achieve desired selectivity and minimise unnecessary supply interruptions.