Pepperl + Fuchs 3 Channel Zener Barrier, ATEX
- RS-stocknr.:
- 280-6614
- Fabrikantnummer:
- Z954
- Fabrikant:
- Pepperl + Fuchs
Subtotaal (1 eenheid)*
€ 187,66
(excl. BTW)
€ 227,07
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 6 stuk(s) vanaf 12 oktober 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 187,66 |
*prijsindicatie
- RS-stocknr.:
- 280-6614
- Fabrikantnummer:
- Z954
- Fabrikant:
- Pepperl + Fuchs
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Pepperl + Fuchs | |
| Number of Channels | 3 | |
| Product Type | Zener Barrier | |
| Barrier Type | Zener Barrier | |
| Mount Type | DIN Rail | |
| Hazardous Area Certification | ATEX | |
| Terminal Type | Screw | |
| Safety Current Resistance | 27.27Ω | |
| IP Rating | IP20 | |
| Supply Voltage | 250V ac | |
| Maximum Safety Current | 383mA | |
| Maximum Safety Voltage | 250V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | IEC, CE, FM, UL | |
| Series | Z954 | |
| Alles selecteren | ||
|---|---|---|
Merk Pepperl + Fuchs | ||
Number of Channels 3 | ||
Product Type Zener Barrier | ||
Barrier Type Zener Barrier | ||
Mount Type DIN Rail | ||
Hazardous Area Certification ATEX | ||
Terminal Type Screw | ||
Safety Current Resistance 27.27Ω | ||
IP Rating IP20 | ||
Supply Voltage 250V ac | ||
Maximum Safety Current 383mA | ||
Maximum Safety Voltage 250V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals IEC, CE, FM, UL | ||
Series Z954 | ||
Vrijgesteld

P&F Dual Channel Zener Diode Barriers
Using a dual channel barrier impedes a direct grounding of the intrinsically safe circuit. The ground is only made in the event of a failure, if the zener diodes conduct. This circuit also suppresses influences of external circuits.
Typical application - thermocouples
Isolation Barriers
Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G
Group and Category
[EEx ia] IIC Class 1, Div1, Groups A-G
Certificate No.
BAS 01 ATEX 7005
Gerelateerde Links
- Pepperl + Fuchs 2 Channel Zener Barrier, ATEX
- Pepperl + Fuchs Zener Barrier, ATEX
- Eaton 3 Channel Zener Barrier, ATEX
- Idec 3 Channel Zener Barrier, ATEX
- Eaton 2 Channel Zener Barrier, ATEX
- Idec 6 Channel Zener Barrier, ATEX
- GEORGIN 2 Channel Double Zener Barrier, ATEX
- Endress+Hauser 2 Channel Zener Barrier, ATEX