Lapp NYY-J 1.5 mm² 3 Core Power Cable, Black PVC, 50m

Afbeelding representeert productcategorie

Subtotaal (1 rol van 50 meter)*

€ 174,95

(excl. BTW)

€ 211,69

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 174,95€ 3,499

*prijsindicatie

RS-stocknr.:
721-0689
Fabrikantnummer:
15500013
Fabrikant:
Lapp
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Lapp

Cross Sectional Area

1.5 mm²

Number of Cores

3

Sheath Colour

Black

Length

50m

Current Rating

19 A

Sheath Material

PVC

Outer Diameter

12mm

CPR Certification

Eca

Voltage Rating

1 kV, 600 V

Conductor Strand Type

Solid

Core Strands

1.38 mm

Conductor Material

Bare Copper

Maximum Operating Temperature

+50°C

Size of Strands

1.38 mm

Series

NYY-J

Standards Met

Euroclass Eca

Insulation Material

PVC

Conductor Resistance

12.1 Ω/km

American Wire Gauge

15 AWG

Fire Behaviour

Flame Retardant

Minimum Operating Temperature

-5°C

Lapp Fixed Installation Power Cable - NYY-J


From Lapp, this NYY-J cable is a widely-used power and control cable that is often found in domestic and commercial electrical wiring. As well as being used in fixed installations, the cable is designed to be used for direct burial, and burial in concrete, providing the operating temperature is adhered to.

The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.

Features and Benefits

• Bare copper conductors
• PVC-based outer sheath
• Suitable for outdoor use
• Flame-retardant according IEC 60332-1-2
• Above, below, flush and recess routing
• Operating temperature during installation: -5°C to +50°C
• Operating temperature in a fixed installation: -40°C to +70°C

Applications

Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;

• Power stations
• Distributor boards
• Subscriber networks


Power Cable

Gerelateerde Links