Lapp NYY-J 16 mm² 5 Core Power Cable, Black PVC, 50m
- RS-stocknr.:
- 721-0734
- Fabrikantnummer:
- 15500833
- Fabrikant:
- Lapp
Subtotaal (1 rol van 50 meter)*
€ 1.349,14
(excl. BTW)
€ 1.632,46
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- 3 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 1.349,14 | € 26,983 |
*prijsindicatie
- RS-stocknr.:
- 721-0734
- Fabrikantnummer:
- 15500833
- Fabrikant:
- Lapp
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lapp | |
| Cross Sectional Area | 16 mm² | |
| Number of Cores | 5 | |
| Sheath Colour | Black | |
| Length | 50m | |
| Current Rating | 79 A | |
| Outer Diameter | 23mm | |
| Sheath Material | PVC | |
| CPR Certification | Eca | |
| Voltage Rating | 1 kV, 600 V | |
| Conductor Strand Type | Solid | |
| Minimum Operating Temperature | +5°C | |
| Standards Met | Euroclass Eca | |
| Fire Behaviour | Flame Retardant | |
| Insulation Material | PVC | |
| Core Strands | 4.51 mm | |
| Conductor Resistance | 1.15 Ω/km | |
| American Wire Gauge | 5 AWG | |
| Series | NYY-J | |
| Conductor Material | Bare Copper | |
| Size of Strands | 4.51 mm | |
| Maximum Operating Temperature | +50°C | |
| Alles selecteren | ||
|---|---|---|
Merk Lapp | ||
Cross Sectional Area 16 mm² | ||
Number of Cores 5 | ||
Sheath Colour Black | ||
Length 50m | ||
Current Rating 79 A | ||
Outer Diameter 23mm | ||
Sheath Material PVC | ||
CPR Certification Eca | ||
Voltage Rating 1 kV, 600 V | ||
Conductor Strand Type Solid | ||
Minimum Operating Temperature +5°C | ||
Standards Met Euroclass Eca | ||
Fire Behaviour Flame Retardant | ||
Insulation Material PVC | ||
Core Strands 4.51 mm | ||
Conductor Resistance 1.15 Ω/km | ||
American Wire Gauge 5 AWG | ||
Series NYY-J | ||
Conductor Material Bare Copper | ||
Size of Strands 4.51 mm | ||
Maximum Operating Temperature +50°C | ||
Lapp Fixed Installation Power Cable - NYY-J
From Lapp, this NYY-J cable is a widely-used power and control cable that is often found in domestic and commercial electrical wiring. As well as being used in fixed installations, the cable is designed to be used for direct burial, and burial in concrete, providing the operating temperature is adhered to.
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
Power Cable
Gerelateerde Links
- Lapp NYY-J NYY-J 4 mm² 4 Core Power Cable 50m
- Lapp NYY-J 16 mm² 3 Core Power Cable 50m
- Lapp NYY-J 1.5 mm² 3 Core Power Cable 50m
- Lapp NYY-J 2.5 mm² 4 Core Power Cable 50m
- Lapp NYY-J 2.5 mm² 5 Core Power Cable 50m
- Lapp NYY-J 6 mm² 3 Core Power Cable 50m
- Lapp NYY-J 1.5 mm² 4 Core Power Cable 50m
- Lapp NYY-J 10 mm² 5 Core Power Cable 50m
